Top 10 Reasons you will love Cadet electric heaters

No items in cart










The Com-Pak Plus - Refurbished

The economical electric in-wall fan heater for smaller areas

The Com-Pak  Plus - Refurbished The economical electric in-wall fan heater for smaller areas The Com-Pak  Plus - Refurbished The economical electric in-wall fan heater for smaller areas
90 Day WarrantyUL Logo

Features and Benefits

  • Creates instant warmth, with quiet operation
  • Takes up very little wall space
  • Nichrome coil element for quick heat
  • Powder coat paint process eliminates sharp metal edges
  • Wall can designed for ease of installation
  • C Model Includes:
    Primary and Secondary Thermal Safeguards
    - High temperature manual reset (push button reset)
    - Over temperature one-time thermal fuse
  • CS Model Includes:
    Primary and Secondary Thermal Safeguards
    - High temperature manual power reset (uses thermostat to reset)
    - Over temperature one-time thermal fuse
  • All refurbished products carry a limited 90 day warranty

General Information

Enjoy quick heat with the Com-Pak Plus by Cadet, our most popular in-wall fan heater. An economical choice that includes our highly regarded safety components, the ComPak Plus takes up very little wall space. These heaters are perfect for smaller areas or larger areas needing the dispersed heat created by multiple heaters.
Cadet recommends a wall-mounted thermostat for optimum performance, or you may prefer the convenience of an optional built-in thermostat.

All refurbished products carry a limited 90 day warranty

Ordering

Need help choosing the right wattage?
Click Here for Heat Selection Tips »

  • Two refurbished models available
    - C Models: Traditional manual push button power reset
    - CS Model: Newer style manual power reset (uses thermostat to reset)
    Complete unit includes wall can, white grill, heater assembly, and heater mounted thermostat.
  • Heater Assembly with stat models require a wall can and grill for new installation. Purchase separately.
  • Heater Assembly only models require a wall can, grill, and thermostat for new installation. Purchase separately.
  • For optimum comfort, a Cadet electronic wall thermostat may be used with any of the ComPak models.
  • Recommended for elevations under 10,000 feet.
  • Limited to stock on hand.

Rough In Dimensions:
8"W x 10.25"H x 4"D
Wall Can Dimensions:
7.875"W x 11.5"H x 4"D
Product Dimensions:
9"W x 12"H

Available Refurbished Models Note: C and CS models are interchangeable (“R” designates Refurbished):

Model# Description 240VWatts
120V
208V240VAmps
120V
208VPriceQTYAdd to Cart
CSC202TWHeater assembly, grill, wall can and thermostat. Complete Unit White2000 15008.33 7.21$84.00
CSC101TWHeater assembly, grill, wall can, and thermostat. White 1000  8.33 $84.00
CSC151TWHeater assembly, grill, wall can, and thermostat. White 1500  12.50 $84.00
CS122Heater assembly only. Wall can, grill, and thermostat sold separately.  1250 9375.21 4.50$58.00
CS101Heater assembly only. Wall can, grill, and thermostat sold separately.   1000  8.33 $58.00
CS102THeater assembly and thermostat only. Wall can and grill sold separately.  1000 7504.17 3.61$63.00
CS202THeater assembly and thermostat only. Wall can and grill sold separately.  2000 15008.33 7.21$63.00
CS101THeater assembly and thermostat only. Wall can and grill sold separately.   1000  8.33 $63.00

Need help choosing the right wattage? Click Here for Heat Selection Tips »

Available Download(s)

Owners Guide

Owner's Guide CS

Owner's Guide C

Architectural Information:

Fan forced electric air heaters shall be UL Listed, factory rated at 120V, 208V, and dual field rated 208V/240V. A painted 20 gauge wall mounting can with six knockouts and 34 cubic inch wiring compartment shall be provided with each complete heater. Each complete heater shall be of unitized construction and attach to the wall can with a single screw and shall be self-contained and completely separate from the wall mounting can.

CS Model Element is of nichrome type wire wrapped on mica insulators with an oversized 16 amp rating at 240V, high temperature manual power reset limit switch and an over-temperature thermal back-up fuse.

C Model Element is of nichrome type wire wrapped on mica insulators with an over- sized 25 amp rating at 240V, high temperature manual reset limit switch and an over-temperature thermal back-up.

A two stage centrifugal blower shall be driven by an impedance protected motor. The motor shall be totally isolated from the heating chamber. Metal grill shall be of one piece, 20-gauge construction and finished with a powder coat paint system.

Technical Information:

Fan heaters and thermostats work best when installed on an inside wall. UL requires heater to be placed a minimum distance of 6" from adjacent surfaces and 41/2" from the floor. Manufacturer recommends installation 12" from all surfaces. Models without built-in thermostat, 1500 watts or less may be ceiling mounted. A 3' (91.44cm) minimum clearance is recommended for furniture or other objects placed directly in front of heater.

NOTE: Manufacturer recommends installing heater assembly after walls are finished. Heater must be cleaned every six months minimum.